+91 9343881685 |080 40985138 Mon - Fri 9:30Am to 7:30PM Chickpet, Bengaluru
Ceritified
ISO 9001:2008
The Best
#1 in Banglore

Heat Shrink

Terminations upto 36 kV For Single Core XLPE/EPR Insulated
Home Heat Shrink Terminations upto 36 kV For Single Core XLPE/EPR Insulated

Terminations upto 36 kV For Single Core XLPE/EPR Insulated

MXS OS/ES-2236

MPL INDIA HEAT SHRINKABLE TERMINATIONS UPTO 36 kV For Single Core XLPE/EPR Insulated Cable

Features

  • All key inputs are produced in-house.
  • Continuous operation temperature-55oC to 120oC.
  • Corrosion resistant and unlimited shelf life.
  • In compliance with IEC-60502-4 / IS-13573.
  • Electrolytic grade connectors.
log

In conformance with IEEE-48,
VDE 0278 & IS: 13573

Specifications:

Test Item of Heat Shrinkable Termination as per IEC-60502-4 / IS:13573

Testing Items U o/U 6.35/11 kV 12.7/22 kV 19/33 kV
A.C. withstand test 29kV, 5min, no flashover 58kV, 5min, no flashover 86kV, 5min, no flashover
Partial discharge test 11kV < 10pc (Max.) 22kV < 10pc (Max.) 33kV < 10pc (Max.)
Thermal Cycles (63 cycles) under 95-100o C 16kV under 95-100o C 32kV under 95-100o C 48kV
Impulse voltage test 75kV no flashover 125kV no flashover 170kV no flashover
A.C. with stand test 16kV, 15 min, no flashover 32kV, 15 min, no flashover 48kV, 15 min, no flashover
Humidity test (Indoor) No flashover, tracking erosion or mechanical damage occured at 300hrs, 8kV No flashover, tracking erosion or mechanical damage occured at 300hrs, 16kV No flashover, tracking erosion or mechanical damage occured at 300hrs, 24kV
Salt Fog test (Outdoor) No flashover, tracking erosion or mechanical damage occured at 1000hrs, 8kV no flashover, tracking No flashover, tracking erosion or mechanical damage occured at 1000hrs, 16kV no flashover, tracking No flashover, tracking erosion or mechanical damage occured at 1000hrs, 24kV no flashover, tracking

Order Reference:

For 11 kV Indoor Terminations (for XLPE Cable)

11 Kv 1 Core
Indoor
Terminations
Cable Size (mm2) Kit Code
1 x 16 - 50 MXSES - 11 Enquire now
1 x 70 - 120 MXSES - 12 Enquire now
1 x 150 - 300 MXSES - 13 Enquire now
1 x 400 - 630 MXSES - 14 Enquire now
1 x 800 - 1000 MXSES - 15 Enquire now

For 11 kV Outdoor Terminations (for XLPE Cable)

11 Kv 1 Core
Outdoor
Terminations
Cable Size (mm2) Kit Code
1 x 25 - 50 MXSOS - 11 Enquire now
1 x 70 - 120 MXSOS - 12 Enquire now
1 x 150 - 300 MXSOS - 13 Enquire now
1 x 400 - 630 MXSOS - 14 Enquire now
1 x 800 - 1000 MXSOS - 15 Enquire now

For 22 kV Indoor Terminations (for XLPE Cable)

22 Kv 1 Core
Indoor
Terminations
Cable Size (mm2) Kit Code
1 x 16 - 50 MXSES - 21 Enquire now
1 x 70 - 150 MXSES - 22 Enquire now
1 x 185 - 300 MXSES - 23 Enquire now
1 x 400 - 630 MXSES - 24 Enquire now
1 x 800 - 1000 MXSES - 25 Enquire now

For 22 kV Outdoor Terminations (for XLPE Cable)

22 Kv 1 Core
Outdoor
Terminations
Cable Size (mm2) Kit Code
1 x 16 - 50 MXSOS - 21 Enquire now
1 x 70 - 150 MXSOS - 22 Enquire now
1 x 185 - 300 MXSOS - 23 Enquire now
1 x 400 - 630 MXSOS - 24 Enquire now
1 x 800 - 1000 MXSOS - 25 Enquire now

For 33 kV Indoor Terminations (for XLPE Cable)

33 Kv 1 Core
Indoor
Terminations
Cable Size (mm2) Kit Code
1 x 25 - 50 MXSES - 31 Enquire now
1 x 70 - 185 MXSES - 32 Enquire now
1 x 240 - 400 MXSES - 33 Enquire now
1 x 500 - 800 MXSES - 34 Enquire now
1 x 1000 MXSES - 35 Enquire now

For 33 kV Outdoor Terminations (for XLPE Cable)

33 Kv 1 Core
Outdoor
Terminations
Cable Size (mm2) Kit Code
1 x 25 - 50 MXSOS - 31 Enquire now
1 x 70 - 185 MXSOS - 32 Enquire now
1 x 240 - 400 MXSOS - 33 Enquire now
1 x 500 - 800 MXSOS - 34 Enquire now
1 x 1000 MXSOS - 35 Enquire now