+91 9343881685 |080 40985138 Mon - Fri 9:30Am to 7:30PM Chickpet, Bengaluru
Ceritified
ISO 9001:2008
The Best
#1 in Banglore

Heat Shrink

Terminations upto 36 kV For PILC Cable
Home Heat Shrink Terminations upto 36 kV For PILC Cable

Terminations upto 36 kV For PILC Cable

MXSO/E-2236

MPL INDIA HEAT SHRINKABLE TERMINATIONS UPTO 36 kV For PILC Cable

Features

  • All key inputs are produced in-house.
  • Continuous operation temperature-55oC to 120oC.
  • Corrosion resistant and unlimited shelf life.
  • In compliance with IEC-60502-4 / IS-13573.
  • Electrolytic grade connectors.
log

In conformance with IEEE-48,
VDE 0278 & IS: 13573.

Specifications

Test Item of Heat Shrinkable Termination as per IEC-60502-4 / IS:13573

Testing Items U o/U 6.35/11 kV 12.7/22 kV 19/33 kV
A.C. withstand test 29kV, 5min, no flashover 58kV, 5min, no flashover 86kV, 5min, no flashover
Partial discharge test 11kV < 10pc (Max.) 22kV < 10pc (Max.) 33kV < 10pc (Max.)
Thermal Cycles (63 cycles) under 95-100o C 16kV under 95-100o C 32kV under 95-100o C 48kV
Impulse voltage test 75kV no flashover 125kV no flashover 170kV no flashover
A.C. with stand test 16kV, 15 min, no flashover 32kV, 15 min, no flashover 48kV, 15 min, no flashover
Humidity test (Indoor) No flashover, tracking erosion or mechanical damage occured at 300hrs, 8kV No flashover, tracking erosion or mechanical damage occured at 300hrs, 16kV No flashover, tracking erosion or mechanical damage occured at 300hrs, 24kV
Salt Fog test (Outdoor) No flashover, tracking erosion or mechanical damage occured at 1000hrs, 8kV no flashover, tracking No flashover, tracking erosion or mechanical damage occured at 1000hrs, 16kV no flashover, tracking No flashover, tracking erosion or mechanical damage occured at 1000hrs, 24kV no flashover, tracking

Ordering Information

CABLE SIZE (Sq. mm) 11 kV, 3 core Indoor Terminations  
3 x 16 - 50 MXSE - 11 Enquire now
3 x 70 - 95 MXSE - 12 Enquire now
3 x 120 - 185 MXSE - 13 Enquire now
3 x 240 - 300 MXSE - 14   Enquire now
3 x 400 - 500 MXSE - 15   Enquire now
CABLE SIZE (Sq. mm) 11 kV , 3 core Outdoor Terminations  
3 x 16 - 50 MXSO - 11 Enquire now
3 x 70 - 95 MXSO - 12 Enquire now
3 x 120 - 185 MXSO - 13 Enquire now
3 x 240 - 300 MXSO - 14   Enquire now
3 x 400 - 500 MXSO - 15   Enquire now
CABLE SIZE (Sq. mm) 22 kV, 3 core Indoor Terminations  
3 x 16 - 50 MXSE - 21 Enquire now
3 x 70 - 120 MXSE - 22 Enquire now
3 x 150 - 225 MXSE - 23 Enquire now
3 x 240 - 400 MXSE - 24   Enquire now
3 x 500 MXSE - 25   Enquire now
CABLE SIZE (Sq. mm) 22 kV, 3 core Outdoor Terminations  
3 x 16 - 50 MXSO - 21 Enquire now
3 x 70 - 120 MXSO - 22 Enquire now
3 x 150 - 225 MXSO - 23 Enquire now
3 x 240 - 400 MXSO - 24   Enquire now
3 x 500 MXSO - 25   Enquire now
CABLE SIZE (Sq. mm) 33 kV, 3 core Indoor Terminations  
3 x 25 - 50 MXSE - 31 Enquire now
3 x 70 - 95 MXSE - 32 Enquire now
3 x 120 - 185 MXSE - 33 Enquire now
3 x 240 - 400 MXSE - 34   Enquire now
CABLE SIZE (Sq. mm) 33 kV, 3 core Outdoor Terminations
3 x 25 - 50 MXSO - 31 Enquire now
3 x 70 - 95 MXSO - 32 Enquire now
3 x 120 - 185 MXSO - 33 Enquire now
3 x 240 - 400 MXSO - 34   Enquire now