Heat Shrink Straight Through Joint upto 36 kV (for 1 Core XLPE/EPR Insulated Cable)

Features

  • In house state-of-the-art compounding technology to provide maximum protection against tracking, corona discharge & dielectric stress.
  • Minimises jointer’s skills.
  • The Products are carefully selected compositions of raw materials to meet the most stringent demands.
  • We also offer tailor-made solutions against specific requirements.
  • Continuous operation temperature-55°C to 120°C.
  • Corrosion resistant and unlimited shelf life.
  • High resistance to impact and abrasion.
  • In compliance to various international specifications and standards (IEC-60502-4 / IS:13573).
  • Electrolytic grade connectors.
Heat Shrink Straight Through Joint upto 36 kV (for 1 Core XLPE/EPR Insulated Cable)

Dimension Chart

Test Item of Heat Shrinkable Straight Through Joint as per IEC-60502-4 / IS:13573

Testing Items U o/U 6.35/11 kV 12.7/22 kV 19/33 kV
A/C withstand test 29kV, 5min, no flashover 58kV, 5min, no flashover 86kV, 5min, no flashover
Partial discharge test 11kV < 10pc (Max.) 22kV < 10pc (Max.) 33kV < 10pc (Max.)
Thermal Cycles (63 cycles) under95-100°C 16kV under95-100°C 32kV under95-100°C 48kV
Impulse voltage test 75kV no flashover 125kV no flashover 170kV no flashover
A/C with stand test 16kV, 15 min, no flashover 32kV, 15 min, no flashover 48kV, 15 min, no flashover

Order Reference:

For 11 kV Straight Joints (for XLPE/EPR Insulated Cable)

11 kV 1 core
Straight
Through Joints
Cable Size (mm2) Kit Code
1 x 16 - 50 MXSSS - 11 Enquire now
1 x 70 - 120 MXSSS - 12 Enquire now
1 x 150 - 225 MXSSS - 13 Enquire now
1 x 240 - 300 MXSSS - 14 Enquire now
1 x 400 - 500 MXSSS - 15 Enquire now
1 x 630 - 1000 MXSSS - 16 Enquire now

For 22 kV Straight Joints (for XLPE/EPR Insulated Cable)

22 kV 1 core
Straight
Through Joints
Cable Size (mm2) Kit Code
1 x 25 - 50 MXSSS - 21 Enquire now
1 x 70 - 150 MXSSS - 22 Enquire now
1 x 185 - 240 MXSSS - 23 Enquire now
1 x 300 - 500 MXSSS - 24 Enquire now
1 x 630 - 800 MXSSS - 25 Enquire now
1 x 1000 MXSSS - 26 Enquire now

For 33 kV Straight Joints (for XLPE/EPR Insulated Cable)

33 kV 1 core
Straight
Through Joints
Cable Size (mm2) Kit Code
1 x 35 - 70 MXSSS - 31 Enquire now
1 x 95 - 150 MXSSS - 32 Enquire now
1 x 240 - 400 MXSSS - 33 Enquire now
1 x 500 - 630 MXSSS - 34 Enquire now
1 x 800 - 1000 MXSSS - 35 Enquire now